Naar inhoud
DREAMESOURCE

Mobiele machines buiten de weg

DS-D101 10,1" cabinedisplay

Display-only terminal for machines that already have a separate controller: a 10.1" 1000 cd/m² screen with four simultaneously visible AHD camera channels. Same enclosure, mounting and connector family as the DS-101, so a machine platform can mix display-only and integrated variants.

Specification

Electrical
Supply voltage
9–36 V DC
Power consumption
500 mA @ 24 V DC
Core
Frequency
2.0 GHz
Memory
2 GB
Storage
32 GB
Operating system
Linux
Display
Screen size
10.1 in
Resolution
1280×800
Brightness
1000 cd/m²
Touchscreen
Capacitive touchscreen
Environment
Operating temperature
-30–+70 °C
Storage temperature
-40–+85 °C
Ingress protection
IP65
Interfaces
CAN
2× CAN 2.0B
Video inputs
4× AHD · 1080P / 720P
Ethernet
RJ45
Serial
1× RS-232 / RS-485
USB
USB programming, update, music
Audio
Built-in 3 W speaker, 15 W external speaker output
Wireless & positioning
Available on request — regional variants confirmed per market and per order
Human interface
Operation
Capacitive touchscreen plus physical keys and rotary encoder
Mechanical
Housing
Aluminium
Connector
2× TE 34-pin (4–1437290–0 / 4–1437290–1) with 3–1447221–4 contacts

Draadloos & positionering

Available on request

LTE bands and GNSS constellations differ by market and are confirmed per order. We do not publish unverified frequency lists.

Dimensions & mounting

Generated from the same specification data as the table below and the datasheet. One source, so they cannot disagree.

FRONT VIEW — DS-D101, 10,1" cabinedisplay.

SCALE
1:1
UNITS
mm
REV
v1.0
DATA SOURCE
specs/ds-d101.json

4× M5×4 ISO-TAPPING 10.0

Mounting
Bracket mount (A8 bracket: 30° tilt · RAM bracket: 60° tilt / 60° swivel) or flush mount. Recommended for indoor cab installation.
Housing
Aluminium

Pinout

Interface 1 — 34-pin

Connector housing
TE 4-1437290-0
Contact
TE 3-1447221-4
Contacts
34
  • 1 CAN1_H CAN1 high
  • 2 RESERVED Reserved (optionally analog ground)
  • 3 RESERVED Reserved (optionally analog ground)
  • 4 SPK_P Speaker output (15 W)
  • 5 SPK_N Speaker output (15 W)
  • 6 GND Analog ground
  • 7 UPDATE Firmware update
  • 8 RESERVED Reserved — optionally coaxial (GND_GPS shield / ANT_GPS centre)
  • 9 RESERVED Reserved — optionally coaxial (GND_GPS shield / ANT_GPS centre)
  • 10 CAN1_L CAN1 low
  • 11 CAN2_H CAN2 high
  • 12 CAN2_L CAN2 low
  • 13 RESERVED Reserved (optionally analog ground)
  • 14 232RX/485_B RS-232 RX / RS-485 B
  • 15 232TX/485_A RS-232 TX / RS-485 A
  • 16 AHD_Y2 AHD 1080P camera 3
  • 17 AHD_Y3 AHD 1080P camera 4
  • 18 LAN_A+ RJ45 Ethernet
  • 19 LAN_A- RJ45 Ethernet
  • 20 GND Analog ground
  • 21 IGNITION Ignition signal
  • 22 USB_DP USB data +
  • 23 USB_DM USB data −
  • 24 AHD_Y0 AHD 1080P camera 1
  • 25 AHD_Y1 AHD 1080P camera 2
  • 26 LAN_B+ RJ45 Ethernet
  • 27 LAN_B- RJ45 Ethernet
  • 28 GND Analog ground
  • 29 DCIN_9-36V Supply positive
  • 30 DCIN_9-36V Supply positive
  • 31 DCIN_GND Supply negative
  • 32 DCIN_GND Supply negative
  • 33 VCC12V_OUT 12 V regulated output, 1 A max
  • 34 VCC5V_OUT 5 V regulated output, 1 A max

Tested to

Reported against these standards in our test documentation. Where the original report cites a GB/T equivalent, both are shown.

  • IEC 60068-2-27 Environmental testing — Part 2-27: Tests — Test Ea and guidance: Shock Reported against GB/T 2423.5 in our Chinese test documentation.
  • IEC 60068-2-30 Environmental testing — Part 2-30: Tests — Test Db: Damp heat, cyclic (12 h + 12 h cycle) Reported against GB/T 2423.4 in our Chinese test documentation.
  • IEC 60529 Degrees of protection provided by enclosures (IP Code) Reported against GB/T 4208. The IP65 / IP67 ratings on our datasheets are cited to this standard.
  • IEC 60068-2-64 Environmental testing — Part 2-64: Tests — Test Fh: Vibration, broadband random and guidance Reported against GB/T 2423.56 in our Chinese test documentation.
  • ISO 10605 Road vehicles — Test methods for electrical disturbances from electrostatic discharge Reported against GB/T 19951 in our Chinese test documentation.
  • IEC 61000-4-4 Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test Reported against GB/T 17626.4 in our Chinese test documentation.
  • ISO 7637-2 Road vehicles — Electrical disturbances from conduction and coupling — Part 2: Electrical transient conduction along supply lines only Reported against GB/T 21437.2 in our Chinese test documentation. Same test method — convertible to an IEC/ISO report without re-testing.
  • ISO 7637-3 Road vehicles — Electrical disturbances from conduction and coupling — Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines Reported against GB/T 21437.3 in our Chinese test documentation.

Certification status

Anything marked Planned is on our roadmap and is not available today. Do not design it into a machine on the assumption that it is.

DS-D101 — Certification status
EMC Directive 2014/30/EU Planned
Radio Equipment Directive 2014/53/EU Planned
RoHS 2011/65/EU Planned
REACH (EC) 1907/2006 Planned
WEEE (Germany) ElektroG Planned
View all certifications

Related models